NDT Techniques
The testing techniques implemented.
NDT Techniques > Magnetic particle testing

This method consists in inducing an intense magnetic field in ferromagnetic material resulting in flux leakage fields at the level of the flaws. Those fields are displayed by highly micronised magnetic tracers laid on the material surface.

The examination can be carried out under visible light with contrast dyes and coloured tracers.

  • Those tracers can be dry or wet :
    • dry tracers: ferromagnetic, very mobile on the testpiece surface and much visible to the eye,
    • wet tracers: carrier liquids are either non-flammable aqueous products or flammable kerosene products.
Extract from COFREND site